Archieven

Amsterdam VU University – Dept. of Earth Sciences – Stable Isotope Laboratory

Amsterdam VU University – Dept. of Earth Sciences – Stable Isotope Laboratory

De Boelelaan 1085, 1081HV Amsterdam, NL

Contact: 
Hubert Vonhof
h.b.vonhof@vu.nl
31(0)205987366/5987308

Research line:       
Geology

Isotopes:       
13C, 15N, 18O, 2H, 32S

Topics
Paleoclimatology
Paleoceanography
Hydrology
Archeology
Forensics
Reservoir studies (oil gas and water)

Instruments:
DI-IRMS Kiel, GC/IRMS, EA/C/IRMS, EA/P/IRMS

Thermo Finnigan MAT 252 with Kiel device
Thermo Finnigan Delta + with Gasbench II
Thermo Finnigan Delta XP with Flash combustion furnace and TC-EA pyrolysis furnace

Amsterdam University – Institute for Biodiversity and Ecosystem Dynamics (IBED)

Amsterdam University – Institute for Biodiversity and Ecosystem Dynamics (IBED)

PO Box 94240, 1090GE Amsterdam
Science Park 904, 1098 XH Amsterdam, NL

Contact
Prof. Karsten kalbitz
K.Kalbitz@uva.nl
31(0)205257434/6637

Cerli Chiara – c.cerli@uva.nl

Research line
Ecology

Topics
With the analyses of C, N, H, and S stable isotopes (δ13C, δ18O, δ15N, δ2H, δ34S) in environmental samples, from soils to sediment and water we study:
–         Effects of changing environmental conditions on the mechanisms and rates of C      stabilization in soils
–         Interactions between land degradation and C sequestration in soils
–         Reconstruction of past environments and climates to improve future predictions
–         Fate of organic pollutants in soils, sediments and water and interactions with organisms exposed to pollution
–         Application of CSIA in forensic science

Isotopes
13C, 15N, 18O, 2H,  32S

Instruments
EA/C/IRMS, EA/P/IRMS, GC/MS, TOC/IRMS

Stable Isotope Ratio Mass Spectrometer IsoPrime 100 (Elementar – Isoprime) connected with:

Elemental Analyzer, vario ISOTOPE cube
·        EA combustion [CO213C, δ18O), N2 (δ15N), H2 (2H), SO234S)]
·        EA pyrolysis (solid) [H2 (2H), CO (δ18O)]
·        EA pyrolysis (liquid) [H2 (2H), CO (δ18O)]

GC/MS, Agilent 7890A GC-MS-FID with N2 cooled PTV injector, GC5 interface
·        [CO213C), N215N), H22H), CO (δ18O)]

Gas concentrator
·        CO2 and CH413C), N2O (δ15N),

High temperature combustion TOC analyzer, TOC cube, TOC cube interface
·        [CO213C), N215N)]
CO213C, δ18O), N215N), H2 (2H), SO234S)

Groningen University – Centre for Isotope Research

Groningen University – Centre for Isotope Research

Nijenborch 6, 9747 AG Groningen, the Netherlands

Contact
Prof. dr. Harro A.J.Meijer
h.a.j.meijer@rug.nl
31(0)503634760

Anita Th. Aerts-Bijma
a.t.aerts-bijma@rug.nl

dr. Dipayan Paul
mailto:d.paul@rug.nl

Research line
Atmospheric research, Radiocarbon dating, Aerosol research, Analytical development

Isotopes
13C, 15N, 17O, 18O, 2H, 14C

Instruments
AMS, DI-IRMS, EA/C/IRMS, EA/P/IRMS, SIRIS

– PrecisION (dual-inlet): Dual-inlet measurements of 13C and 18O in CO2
– PrecisION-Elementar PyroCUBE: Stable isotopes of C, H, N, O and S
– DI-Optima: Dual-inlet measurements of 13C and 18O in CO2
– Air-Optima: O2/N2 in air samples
– Isoprime-100-Elementar IsotopeCUBE:Stable isotopes of C and N
– LGR liquid water isotopes analyzer: 2H, 17O, 18O in water
– Isoprime-10: Stable isotopes of O and H
– Aerodyne TILDAS: 13C, 17O and 18O of CO2-in-air

– PrecisION-Sunset EC/OC analyzer: 13C measurements in aerosol samples.

(Prof. dr. Ulrike Dusek, u.dusek@rug.nl)

– MICADAS: Radiocarbon (14C) (AMS)
The MICADAS comes equipped with a carbonate handling system and an elemental analyzer for direct CO2 analysis of small samples (20-100 µgC).

(Prof. dr. Michael W. Dee m.w.dee@rug.nl and dr. Safoora Kamjan s.kamjan@rug.nl)

Research Institute for Chromatography – Research & Development

Research Institute for Chromatography – Research & Development

Pres. Kennedypark 26
8500 Kortrijk, Belgium

Contact
Emmie Dumont
emmied@richrom.com
32(0)56204031

Research line
Analytical development

Topics
optimization of the chromatographic separation before IRMS
implementation of 2D-GC and 2D-LC
complex natural samples.

Isotopes
13C, 15N, 2H

Instruments
GC/Py/IRMS, 2D-GC/Py/IRMS, LC/C/IRMS

GC-C/Py-IRMS (Agilent GC 7890 + Thermo delta V advantage)
2D-GC-C/Py-IRMS
LC-C-IRMS (All Thermo)